# Spore test log

A printable spore test log: date, sterilizer, test lot, lab, result and the action after a failed test, plus how often states require it.

General information, not legal advice. Check the source and your local health department before you rely on it.

## How often to spore test an autoclave

It depends on who sets your rule. CDC's guideline for healthcare facilities says steam sterilizers should be tested with biological indicators at least weekly ([CDC Guideline for Disinfection and Sterilization in Healthcare Facilities, sterilizing practices](https://www.cdc.gov/infection-control/hcp/disinfection-sterilization/sterilizing-practices.html) (checked November 26, 2026)). Body art rules are set by each state, and they differ: Texas requires a spore test by an approved laboratory each calendar month ([25 Tex. Admin. Code 229.407, Sterilization (Cornell LII reproduction)](https://www.law.cornell.edu/regulations/texas/25-Tex-Admin-Code-SS-229-407) (checked November 26, 2026)); Florida requires one at least every 40 hours of autoclave operation and no less than quarterly, read by an independent laboratory ([Fla. Admin. Code R. 64E-28.007 (Cornell LII reproduction; rule effective 2012-09-05 per flrules.org)](https://www.law.cornell.edu/regulations/florida/Fla-Admin-Code-Ann-R-64E-28-007) (checked November 26, 2026)). Follow your state's rule, and test more often if you run a lot of cycles. Your county health department can tell you if it adds its own.

## What to do after a failed test

Write it down the same day. CDC's guideline says that when a steam sterilizer's mechanical and chemical readings were normal, the spore test should be repeated right away, and if repeat tests are still positive, the sterilizer should be taken out of use until it's serviced ([CDC Guideline for Disinfection and Sterilization in Healthcare Facilities, sterilizing practices](https://www.cdc.gov/infection-control/hcp/disinfection-sterilization/sterilizing-practices.html) (checked November 26, 2026)). Note which loads ran since the last passing test, in case your health department asks for them to be reprocessed. The "action" column is where that goes: what was pulled, what was run again, when the retest passed. Some states also ask you to report a failed test; check yours.

## Keep the lab reports with the log

Mail-in services send a report for each test. File it with the log line it belongs to. Texas and Florida both require sterilization records kept for two years (sources above); other states set their own period.

## A reminder before the next one is due

In the software's binder, set your testing schedule and the binder reminds you before the next test is due. A failed result stays flagged on the binder and the inspector's view until the action and a passing retest are logged. See [records and inspections](/features/records-and-inspections).

---