# Autoclave log sheet

A printable autoclave log: date, time, cycle number, sterilizer, temperature, pressure, time at temperature, indicator result and initials.

General information, not legal advice. Check the source and your local health department before you rely on it.

## What goes on an autoclave log

Each cycle gets its own line, written when it finishes. CDC's sterilization guideline describes checking each cycle's time and temperature from the sterilizer's record and its pressure from the gauge, and putting a chemical indicator on the outside of every pack, preferably one inside too ([CDC Guideline for Disinfection and Sterilization in Healthcare Facilities, sterilizing practices](https://www.cdc.gov/infection-control/hcp/disinfection-sterilization/sterilizing-practices.html) (checked November 26, 2026)). The log turns those checks into a record: if an indicator didn't change color, the line says so and the notes say what you did.

Writing the cycle number on every pouch in the load ties each instrument back to its line. If anything ever goes wrong with a cycle, you know exactly which pouches to pull.

## What your state may add

State rules for body art sterilizers differ in what the log must hold and how long you keep it. Texas, for example, requires a sterilization log with the date, the quantity and type of instruments and who sterilized them, kept at the studio for at least two years from the last entry ([25 Tex. Admin. Code 229.407, Sterilization (Cornell LII reproduction)](https://www.law.cornell.edu/regulations/texas/25-Tex-Admin-Code-SS-229-407) (checked November 26, 2026)). Florida requires the autoclave log to show cumulative run time and the quantity and types of items sterilized each day, kept two years ([Fla. Admin. Code R. 64E-28.007 (Cornell LII reproduction; rule effective 2012-09-05 per flrules.org)](https://www.law.cornell.edu/regulations/florida/Fla-Admin-Code-Ann-R-64E-28-007) (checked November 26, 2026)). If your state asks for something this sheet doesn't have, add a column; check your health department's rule for the exact list.

## Single-use shops still keep one

A shop that uses only pre-sterilized single-use needles and tubes may not run an autoclave at all. If yours does run one, even only for grips or forceps, keep the log.

## From clipboard to binder

The same columns live in the binder in the software. Add a line from your phone next to the sterilizer, carry the sterilizer, temperature and pressure over from the last line, and a failed indicator stays flagged until you write what was done. An inspector's link and the export show the whole log by date. See [records and inspections](/features/records-and-inspections).

---

Page: https://tattoo.greatwork.company/templates/autoclave-log
Last updated: 2026-11-26
By Jake at Great Work. Questions or corrections: hello@greatwork.company