Autoclave log sheet

One line per sterilizer cycle: when it ran, the cycle number written on the pouches, which unit, the temperature, pressure and time at temperature from the display or printout, the chemical indicator result, and who ran it. It's the record that shows each reused instrument went through a cycle that worked.

This is a template and general information, not legal advice. Rules differ by state and sometimes by county, so check yours with your local health department before you use it.

State rules last checked .

Spotted something wrong? Email hello@greatwork.company and we'll fix it.

The blank sheet

One line for every sterilizer cycle you run, so an inspector can match any instrument back to the cycle that cleaned it. The printed sheet has 18 lines; here are the first few.

Autoclave log, blank sheet
DateTime startedCycle or load numberSterilizerTemperature (°F)Pressure (psi)Time at temperature (min)Chemical indicatorInitialsNotes

What each column is for

Each column, with its Spanish heading as printed on the Spanish version, and why it's there.

DateFecha
Inspectors read the log by date first.
Time startedHora de inicio
Two cycles on one day are told apart by the start time.
Cycle or load numberNúmero de ciclo o carga
The number written on the pouches, so instruments trace back to this line.
SterilizerEsterilizador
Which unit ran it, when a studio has more than one.
TemperatureTemperatura
Read from the sterilizer's display or printout at the end of the cycle.
PressurePresión
Steam sterilizers show pressure; leave it blank on a dry heat unit.
Time at temperatureTiempo a temperatura
How long the load held the temperature, from the display or printout.
Chemical indicatorIndicador químico
The color change on the strip or pouch, checked before anything is used.
InitialsIniciales
Who ran the cycle and checked the result.
NotesNotas
Anything off: a failed indicator, a wet pack, a cycle run again.

A filled-in example

Example values only. Use the cycle times and temperatures your sterilizer's manufacturer sets.

Autoclave log, example entries
DateTime startedCycle or load numberSterilizerTemperature (°F)Pressure (psi)Time at temperature (min)Chemical indicatorInitialsNotes
Nov 39:40 AM1103-1Unit 12501530PassJR
Nov 32:15 PM1103-2Unit 12501530PassJR
Nov 410:05 AM1104-1Unit 12501530FailMCPouch didn't change color. Load run again as 1104-2.

Keep this log in the app

In the app, each line is a binder entry with these same columns, so moving off paper means no retyping. Entries are dated, signed with the artist's name, and come out in the inspection binder export with the lab reports and manifests attached.

How often a state or county wants each test, and how long it wants the logs kept, differs. Tattoo laws by state covers what each state asks for.

What goes on an autoclave log

Each cycle gets its own line, written when it finishes. CDC's sterilization guideline describes checking each cycle's time and temperature from the sterilizer's record and its pressure from the gauge, and putting a chemical indicator on the outside of every pack, preferably one inside too (CDC Guideline for Disinfection and Sterilization in Healthcare Facilities, sterilizing practices (checked November 26, 2026)). The log turns those checks into a record: if an indicator didn't change color, the line says so and the notes say what you did.

Writing the cycle number on every pouch in the load ties each instrument back to its line. If anything ever goes wrong with a cycle, you know exactly which pouches to pull.

What your state may add

State rules for body art sterilizers differ in what the log must hold and how long you keep it. Texas, for example, requires a sterilization log with the date, the quantity and type of instruments and who sterilized them, kept at the studio for at least two years from the last entry (25 Tex. Admin. Code 229.407, Sterilization (Cornell LII reproduction) (checked November 26, 2026)). Florida requires the autoclave log to show cumulative run time and the quantity and types of items sterilized each day, kept two years (Fla. Admin. Code R. 64E-28.007 (Cornell LII reproduction; rule effective 2012-09-05 per flrules.org) (checked November 26, 2026)). If your state asks for something this sheet doesn't have, add a column; check your health department's rule for the exact list.

Single-use shops still keep one

A shop that uses only pre-sterilized single-use needles and tubes may not run an autoclave at all. If yours does run one, even only for grips or forceps, keep the log.

From clipboard to binder

The same columns live in the binder in the software. Add a line from your phone next to the sterilizer, carry the sterilizer, temperature and pressure over from the last line, and a failed indicator stays flagged until you write what was done. An inspector's link and the export show the whole log by date. See records and inspections.